Patient Monitor, 6-Parameter Patient Monitor, 15-Inch Patient Monitor manufacturer / supplier in China, offering 2015 Promotion! ! ! 15-Inch 6-Parameter Patient Monitor (RPM-9000E) -Fanny, 2 MHz Fetal Monitor Fetal Heartbeat Baby Monitor Pocket Fetal Doppler with Ce Certificate, 2MHz Probe Color LCD Display Pocket Fetal Doppler Prenatal Baby Heart Rate Monitor and so on.

Gold Member Since 2015
Audited Supplier
Supplier Homepage Products Patient Monitoring 2015 Promotion! ! ! 15-Inch 6-Parameter Patient Monitor (RPM-9000E) -Fanny

2015 Promotion! ! ! 15-Inch 6-Parameter Patient Monitor (RPM-9000E) -Fanny

Get Latest Price
Purchase Qty. / Reference FOB Price
1-4 Pieces US $900
5-9 Pieces US $850
10-49 Pieces US $800
50-99 Pieces US $650
100+ Pieces US $500
Production Capacity: 500 Set Per Month
Transport Package: Standard Export Carton with Foam
Payment Terms: T/T, Western Union
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient/Fetal/Maternal Monitor
Certification: CE, ISO13485
Group: Adult
Condition: Brandnew
Model: Rpm-9000e

You Might Also Like

Loading...

Basic Info

Model NO.: RPM-9000E
Origin of Place: Beijing, China
Screen: 15-Inch
Standard Parameter: Pr, SpO2, NIBP, ECG, Resp, Temp
Optional Parameter: Printer, Etco2, IBP, Trolley, Wall Mount
Trademark: OEM
Specification: CE and ISO13485
Origin: Beijing, China

Product Description

 Features:

Ergonomic design, portable, convenient for use
15" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
Unique digital SpO2 technology can work accurate during motion and low perfusion
Anti AC & high-frequency electrosurgical & defibrillator's interference
Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
Audible & visual alarm available, adjustable
Patient information management function
Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
Flexible data storage & transfer/software upgrading based on USB
Wired/wireless networking with central monitoring system, up to 64 beds in one group
Built-in 3 trace thermal recorder for printing real-time and historical data
Multi-language I. E. English, Spanish, French, Italian, Turkish, German, Russian etc.
Super long life rechargeable dual lead-acid battery (optional) upto 4 hours of working time
Suitable for adult, pediatrics and neonate patients
Standard configuration:

ECG, NIBP, SpO2, TEMP, RESP, PR, Rechargeable lead-acid battery
Optional:

Dual TEMP
Dual IBP
EtCO2 (side stream)
CO (Cardiac Output)
Nellcor SpO2 module
Thermal recorder
Artema Multi-gas
Wall mount
Trolley
Rechargeable Lithium-Ion Battery
Specification:

ECG

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ± 1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope: ± 0.8mV
Precision: < ± 0.05mV

NIBP

Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: Dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg), 13.3kPa(100 mmHg), 16.0kPa(120 mmHg)
18.6kPa(140 mmHg), 20.0kPa(150 mmHg), 21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size: 1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
In -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static pressure: ± 3mmHg
Pulse rate: ± 2%

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute-100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ± 1 time/minute

Invasive blood pressure (optional)

Single/double path
Type: Direct and continuous detection
Scope: -6.67kPa(-50mmHg)_46.67kPa(350mmHg)
Precision: Below 13.33kPa(100mmHg) ± 0.27kPa(2mmHg) 13.33k
Pa(100mmHg) above ± 2%
Frequency response: DC-12Hz
Input resistance: Not less than 500kohm
Sensitivity of sensor: 5μ V/V/mmHg
Motivation voltage: 5V (DC)
Accuracy of sensor: ± 2%Isolation voltage: 4 kV